1.
Chinese Journal of Radiological Health ; (6): 316-321, 2023.
Article in Chinese | WPRIM | ID: wpr-978436

ABSTRACT

Objective To develop a reasonable plan of monitoring personal internal exposure dose. Methods This paper introduced the methods of monitoring the individual dose and direct measurement of three representative radionuclides. Results The maximum monitoring periods were determined according to the radionuclide retention characteristics and the reporting standards and requirements, which were m(1)/m(T/2) ≤ 3 and m(T/2)/m(T) ≤ 3. The lower detection limit of the instrument was derived from the monitoring periods and the annual radionuclide intake limit, which should be lower than the derived method detection limit of the corresponding radionuclide. Then the measuring duration of the instrument that meets the corresponding conditions was derived from the derived method detection limit of the instrument and the maximum monitoring period. Conclusion Our results provide a reference for the formulation of a plan of monitoring personal internal exposure dose.